Products
HKXR POWER

PLC / HMI • PUMP CONTROL • PROCESS AUTOMATION

Control & PLC Panels

PLC, HMI and electrical control panels for equipment automation, pump control and process sequences.

Control hardwarePLC / I/O / equipment interfaces
Operator interfaceHMI / pushbuttons / alarms
Control definitionSequence / interlocks / communication
Project inputI/O list / control narrative

Choose configuration options below, or contact us directly.

Control & PLC Panels

01 Technical data

Configuration & project information

Choose the arrangement below and add the details you have.

Configuration choices

Panel hardware
PLC, I/O, power supplies, terminals and equipment connections.
Operator interface
HMI, pushbuttons, indicator lights and alarms.
Requested scope
Hardware assembly, PLC programming and HMI configuration as separate selections.

Information to provide

Signals
DI / DO / AI / AO counts, signal types and field equipment.
Control narrative
Sequences, interlocks, operating modes and alarms.
Interfaces
P&ID, protocols, network topology and equipment models.

02 Application engineering

Applications

01

Pump and treatment sequences

A PLC panel connects level, pressure and flow instruments with pump and valve commands. The I/O list and operating narrative define duty/standby sequences, alarms and interlocks. Instrument signal types, communication links and loss-of-signal behaviour must be agreed; panel hardware, programming and commissioning responsibilities need clearly defined boundaries.

02

Machines and production lines

Machine control panels connect sensors, actuators, drives and operator interfaces to the control system. I/O quantities, cycle sequences and network architecture determine the PLC hardware and cabinet layout. Safety functions require a separate risk assessment and suitable architecture; software scope, interfaces and handover documents belong in the project specification.

03

Process auxiliaries and supervision

Dust extraction, dosing and other process auxiliaries need coordinated field signals and permissives from the main process. Signal lists and communication protocols define the connection to PLC, HMI or supervisory systems. Cable segregation, shielding, terminal allocation and agreed alarm handling support a clear, maintainable control interface.

03 Define your configuration

Select your configuration

All fields are optional. Choose one or more options as indicated; use Other for a custom requirement.

Application

Select all that apply.

Operator interface

Select one.

Requested scope

Select all that apply.

Project information

Select all that apply.

Additional requirements

Supply voltage requested

Enter details

I/O requirement

Enter details

Enclosure requirement

Enter details

Component preference

Enter details

Communication requirement

Enter details

Supply frequency

Enter details

Current requirement (A)

Enter details

Electrical values entered here are requested requirements. Equipment ratings must match the selected model and its technical datasheet.

Hardware, software, source files and commissioning are separate scope items.

04 Construction and options

Construction & configuration options

Controller & I/O

The controller and I/O arrangement organises digital and analogue signals, signal types and specified spare I/O.

Operator interface

HMI, pushbuttons and indication provide the selected operator interface. Screen development and software delivery are separate from hardware installation.

Equipment interfaces

Connections to drives, instruments and actuators link the control cabinet to the field equipment.

Communication

Network connections and communication interfaces follow the selected equipment and documented protocols. Remote-monitoring functions are separate scope items.

Control power & protection

Control power supplies, circuit protection and isolation support the cabinet's control and auxiliary circuits.

Software & functional checks

Programming, source files, backups and commissioning are separate deliverables. Functional checks follow the agreed control sequence and acceptance scope.

05 Applicable standards and requirements

Standards & engineering

Control & PLC Panels
Project specification
Provide the applicable standard editions, destination requirements and tender specification.
Rating schedule
Keep the electrical ratings and installation limits linked to the selected model.
Verification documents
Identify the required inspection records, test reports and acceptance criteria.
Supply scope
Specify hardware assembly, PLC programming, HMI configuration, source-file handover and remote or on-site support individually. Availability and deliverables require confirmation; requested options do not confirm inclusion.
Request compliance and engineering documents

06 Manufacturing & Projects

From Production to Projects

Manufacturing
01Manufacturing
Watch assembly video Open video ↗
Assembly & wiring
02Assembly & wiring
Watch wiring video Open video ↗
Control room application
03Control room application

Project documentation

Project Documents

Control & PLC Panels

Documents you can send

Send existing drawings or lists. You can start an inquiry without a complete document package.

  • I/O list
  • Control narrative / sequence of operation
  • P&ID and network topology
  • Wiring and software handover schedule
Send project information

Documents to request

Ask for the following documents for the selected equipment. Document availability and delivery stage are agreed with the quotation.

  • Configuration and component schedule
  • Arrangement and power / control wiring drawings
  • Model datasheets and applicable verification records
Request equipment documents

07 Decision support

Frequently asked questions

Control & PLC Panels
What belongs in the I/O list?

List digital and analogue inputs and outputs, signal types, field devices and spare channels. Include device tags to link signals to the drawings.

Can I request hardware and software separately?

Yes. Select hardware assembly, PLC programming and HMI configuration independently. State source-file handover and commissioning requirements separately.

What is needed for communication interfaces?

Provide equipment models, protocols, network topology and signal boundaries. Identify which system sends commands and receives status.

Let’s discuss your project

Request a quote

Share any available details, or contact us directly via WhatsApp.

Alternative contact

WhatsApp

Selected configuration

Select the main project parameters.

Edit configuration

Please attach your SLD, BOM, drawings or technical specifications in WhatsApp or your email app. Files are not uploaded on this page.

Send by email

Fields marked * are required for email only. Review the draft, add attachments and send it in your email app. WhatsApp needs no form fields.

We use the details you submit to respond to this enquiry. Privacy.