Products
HKXR POWER

Underground distribution • Residential developments • Commercial sites • Industrial parks

Pad-Mounted Transformers

Pad-mounted transformer solutions for underground distribution and site power systems.

Rated capacity1φ 15–250 / 3φ 10–1600 kVA
Primary voltageModel-specific; see single-/three-phase notes
PhasesSingle-phase / Three-phase
ApplicationsUnderground distribution / Residential developments

Single-phase ratings: 15–250 kVA. Three-phase ratings: 10–1600 kVA. Three-phase HV ratings run from 6 to 36 kV; single-phase paired HV ratings include 13.8/7.967, 20/11.547, 30/17.32 and 33/19 kV.

Pad-Mounted Transformers

01 Technical data

Factory product specifications

Single-phase ratings: 15–250 kVA. Three-phase ratings: 10–1600 kVA. Three-phase HV ratings run from 6 to 36 kV; single-phase paired HV ratings include 13.8/7.967, 20/11.547, 30/17.32 and 33/19 kV.

Product type
Pad-Mounted Transformers
Rated capacity
1φ 15–250 / 3φ 10–1600 kVA
Primary voltage
Model-specific; see single-/three-phase notes
Secondary voltage
1φ: 120/240 V / 240/480 V; 3φ: 0.4 / 0.415 kV
Product series
ZGS(9/11) / Single-phase pad-mounted
Phases
Single-phase / Three-phase
Vector groups — three-phase
Yyn0 / Dyn11
Tap ranges
±2 × 2.5% / ±3 × 2.5% / ±5%

02 Application engineering

Applications

Pad-mounted transformer solutions for underground distribution and site power systems.

01

Underground distribution networks

Transformation at ground level in underground MV cable networks, with protected compartments instead of a substation building. Suits cities and new developments where overhead lines are restricted and cable terminations must be enclosed.

02

Commercial complexes and buildings

Shopping centers, office parks, hospitals and mixed-use complexes served from a utility cable ring. The compact footprint allows installation near the load, and fusing and switching options can be agreed with the network operator.

03

Renewable and private distribution

Collector and auxiliary transformation for solar farms, wind sites and mine or plant private networks. Ground-level compartments simplify cable entry from underground collector circuits and can be configured to the owner protection scheme.

Where to apply

  • Underground distribution
  • Renewable and private networks
  • Commercial complexes
  • Campuses and institutions
  • Residential developments
  • Urban infrastructure

03 Define your configuration

Configure your transformer

Select capacity, voltage and phases using the manufacturer catalogue values as references, or enter your requirements under Other. The manufacturer must confirm the proposed combination.

Rated capacity

Primary voltage

Secondary voltage

Phases

Additional options

Tap range

Vector group

Short-circuit impedance

Feed type

04 Construction and options

Technical resources and options

Typical configuration

Lockable steel enclosure with separate high-voltage and low-voltage compartments and tamper-resistant access, installed at ground level beside the load.

Available option

Feed configuration: radial, loop or terminal feed, with the MV switching and bushing arrangement matched to the cable network layout and agreed per project.

Available option

MV connection and cable termination: separable connectors, bushing wells and inserts, or cable-box terminations suited to the specified cable type.

Available option

Fusing and switching: protective fuses, load-break switching and arrester provisions can be built in according to the network protection philosophy.

Available option

LV compartment: LV terminals or busbars, protected outgoing circuits and space for metering or auxiliary equipment according to the utility requirement and the applicable project technical specification.

Project engineering

Plinth and cable entry: concrete or fabricated base with cable pit, oil containment and sealing against water and vermin ingress, dimensioned to the site layout. Environmental engineering for variable outdoor exposure such as UV, rain, wind and coastal or industrial atmosphere depending on the site: corrosion protection, ventilation, flood-risk placement and project-specific protection or monitoring are confirmed at project level.

05 Applicable standards and requirements

Standards & engineering

Project standards and certification
Generic international market; standards and certification must be selected from the actual destination and project.
Network and utility requirements
Configuration subject to utility and engineering review.
Technical parameters
Single-phase ratings: 15–250 kVA. Three-phase ratings: 10–1600 kVA. Three-phase HV ratings run from 6 to 36 kV; single-phase paired HV ratings include 13.8/7.967, 20/11.547, 30/17.32 and 33/19 kV.
Tap ranges
±2 × 2.5% / ±3 × 2.5% / ±5%
Request compliance and engineering documents

06 Manufacturing process

From production to testing

Production — Pad-Mounted Transformers
01Production
Assembly — Pad-Mounted Transformers
02Assembly
Testing — Pad-Mounted Transformers
03Testing

Downloads & support

Technical documents

HKXR POWER Technical Selection Guide

Guide for initial technical selection of distribution, power, dry-type, pole-mounted and pad-mounted transformers.

Unlock download

Complete your details to download the HKXR POWER Technical Selection Guide.

07 Decision support

Frequently asked questions

When should Pad-Mounted Transformers be selected instead of Pole-Mounted Transformers?

Choose Pad-Mounted Transformers when the main duties are Underground distribution and Renewable and private networks; compare Pole-Mounted Transformers when Overhead distribution and Utility distribution feeders better match the site. Final selection depends on the installation environment, network topology, fire or oil-containment requirements, rating and project specification.

How should the main configuration options for Pad-Mounted Transformers be selected?

Key choices include radial / loop / terminal feed, MV cable connectors and switching and fusing. Select them according to the load profile, connection arrangement, installation environment, protection philosophy and utility/EPC specification; items shown as options or project engineering are not automatic standard equipment.

What installation conditions should be confirmed for Pad-Mounted Transformers projects?

Confirm ambient temperature, altitude, humidity, dust or corrosion exposure, indoor/outdoor location, ventilation, access and maintenance clearances. For applications such as Underground distribution, Renewable and private networks and Commercial complexes, cooling, enclosure or insulation and protection should be reviewed during engineering rather than assuming one environmental class for every project.

Which standards and utility/project requirements should be confirmed?

Generic international market; standards and certification must be selected from the actual destination and project. Final losses, temperature rise, impedance, taps, accessories, tests and documentation must be checked against the applicable project specification; this page does not imply automatic approval by any authority.

What tests, drawings and documents should be agreed before the purchase order?

Confirm the applicable routine tests, general arrangement drawings, electrical datasheet, accessory list and inspection/test documents before manufacturing. Type or special tests, witnessing and additional reports should be specified when the project requires them. For Pad-Mounted Transformers, also confirm site-specific environmental and installation engineering.

What information does HKXR need to prepare a technical quotation?

Provide at least Rated capacity, Primary voltage, Secondary voltage, Phases, the selected radial / loop / terminal feed / MV cable connectors options, installation conditions and the applicable project or utility specification. If available, attach the SLD, datasheet or tender specification so the configuration can be reviewed before quotation.

Let’s discuss your project

Request a quote

Review your configuration and continue via WhatsApp.

Alternative contact

WhatsApp

Selected configuration

Select the main project parameters.

Edit configuration

Attach the technical data sheet, single-line diagram, photos or project documents. Send the file manually via WhatsApp.

Send by email